Refrigerator Medium Severity
E5 Appliance Error Code

Maytag Refrigerator E5 Error: Ice maker fault

What Does Maytag Refrigerator Error Code E5 Mean? E5 on a Maytag refrigerator indicates an Ice Maker fault. This code appears on Maytag Ice2O, MFI, and MFX French door and side-by-side models when the ice maker module has not completed a harvest cycle within the maximum allowed time window. The board sets E5 to distinguish […]

Quick Assessment

Answer to continue safely

Is it safe to keep using?

Yes. E5 relates only to the ice maker module. The refrigerator and freezer sections continue operating normally. Food safety is not affected, though ice production is unavailable.

Can I reset the code?

Yes. Pressing the ice maker test button initiates a fresh harvest cycle and clears E5 if the underlying module is functional. If the module has failed mechanically, E5 returns after the next cycle attempt.

When to stop immediately?

Stop if you notice: E5 returns immediately after the test cycle completes, Harvest motor is audible but the ejector arm does not rotate.

Symptoms You May Notice

Ice maker has stopped producing ice for 24 hours or more

The Ice2O or MFI ice maker module exceeds its no-harvest timeout and the board sets E5, confirming that the production halt is not a temporary pause.

E5 appears on the display alongside the ice maker icon

The Maytag MFX or MFI French door control panel shows E5 with the ice maker indicator active, distinguishing the code from other E-series faults.

Ice bin is empty and no water fill is audible

No water valve activation sound is heard at the start of a fill cycle, indicating the ice maker module has halted its operational sequence.

Water fill sound absent

The normal water-valve click and fill rush at the ice maker are no longer audible.

Possible Causes

1

Ice maker bail arm in the raised (off) position

The wire bail arm on Maytag MFI and MFX ice makers automatically raises when the bin is full. If it is stuck up or was manually raised, E5 may be set after the extended-off timeout.

DIY Possible
2

Freezer temperature too warm for ice production

The ice maker module requires freezer temperature at or below 15 °F to initiate a harvest cycle. If SY EF or a defrost fault has allowed the freezer to warm, E5 follows as a secondary code.

DIY Possible
3

Failed ice maker module (harvest motor or thermostat)

The ice maker module's internal harvest motor or the ejector arm thermostat has failed, preventing the module from completing a harvest cycle.

Requires Professional

Safe Checks You Can Do

These checks are safe for homeowners. No disassembly required. Do not remove panels or access internal components.
  1. 1

    Check the bail arm position and reset the ice maker

    Open the freezer door and locate the wire bail arm on the ice maker module. It should be in the down (active) position. If it is raised, lower it by hand. Press and hold the ice maker test button (small button on the module face) for three seconds to initiate a test cycle and clear E5.

    On Maytag MFX French door models the ice maker is in the upper freezer drawer compartment. On MFI side-by-side models it is on the left wall of the freezer section.

  2. 2

    Verify freezer temperature is at or below 15 °F

    Place an appliance thermometer in the center of the freezer for one hour and read the actual temperature. If it reads above 15 °F, address any active SY EF or dF codes first before diagnosing the ice maker module independently.

    Ice production resumes automatically on Maytag Ice2O models once freezer temperature drops below 15 °F and the bail arm is in the down position. Allow two to four hours after correct temperature is confirmed.

When to Call a Professional

Contact a qualified technician if:

  • Ice maker module draws no current on the harvest motor test
  • Water inlet valve solenoid for the ice maker tests open on continuity
  • E5 persists after confirming correct freezer temperature and bail arm position

Need Professional Help?

Find qualified technicians in your area for proper diagnostics and repair.

Refrigerator Repair Service Schedule Appointment